Automation and Process control

: (160) products
Image
Product code
Description
Datasheet
Manufacturer
Manufacturer code
Stock
Price
QTY
Adapter EZoFlash DIP28_B1Image of Adapter EZoFlash DIP28_B1

Adapter EZoFlash DIP28_B1


Supports chips Flash AT29C/29EExxx >
 
 
3
pc
1+ 7.30 BGN
3+ 6.90 BGN
5+ 6.60 BGN
10+ 6.30 BGN
view more
Adapter EZoFlash DIP32_CImage of Adapter EZoFlash DIP32_C

Adapter EZoFlash DIP32_C


Supports chips Selected device Flash28Fxxx > 28F00x 8bit > i28F001BX-T,
 
 
4
pc
1+ 7.80 BGN
3+ 7.40 BGN
5+ 7.05 BGN
10+ 6.75 BGN
view more
Adapter EZoFlash DIP24B1Image of Adapter EZoFlash DIP24B1

Adapter EZoFlash DIP24B1


Supports chips TMS2532, TMS2532A, HN462532, NTE2532, NTE2532A,
 
 
1
pc
1+ 7.80 BGN
Cable for programmer 6P/150mmImage of Cable for programmer 6P/150mm
 
 
0
pc
1+ 1.50 BGN
3+ 1.40 BGN
5+ 1.32 BGN
10+ 1.25 BGN
view more
Converter USB-RS232/RS485/UARTTTLImage of Converter USB-RS232/RS485/UARTTTL

Converter USB-RS232/RS485/UARTTTL


The device is a 3 in 1 universal converter. It can be used as RS232, RS485 or UART TTL converter. USB RS232 485 UART TTL is based on chip FT232RL, it has normal COM port made with two serial converters MAX232 and converter 485 made with chip MAX485. Connection parameters can be set on an operating system at speed: from 110 to 921600bps. It is applicable for communication with different microcontrollers such as PIC, Atmel and other with TTL serial connection. For connecting devices with RS232 or industrial RS485 interface through computer USB port. Specifications: Communication interface: RS232, RS485 and UART TTL Connecting RS232 via DB9 Male Connector Serial Speed: from 110 up to 921600bps Supply Voltage DC 5V (USB) LED indication for PWR supply voltage LED indication for RX, TX receiving and transmission PCB Size: 57 х 35mm Description: - socket X1 USB Cable Type A to a computer - socket X2 RS232 Female Cable - pin header X3 VCC – Output 5V DC TX – UART output RX – UART input GND – Ground 0V B – RS485 signal line B A – RS485 signal line A - pin header X4 Jumper for terminating resistor switch on 120Ω Signalling: - red LED D3 (PWR) – power supply is on - yellow LED D1 (RX) – turns on when receiving data - green LED D2 (TX) – turns on when sending data Setting a working mode (from MProg programme): - USB to RS232, UART C3 = “I/O” - USB to RS485 C3 = “TXDEN” Loading settings via Mprog: - Menu File>Open RS23 and UART – „USB to RS232 UART.ept“ RS485 – “USB to RS485.ept” Note: - Once settings’ loading is completed, the device needs to be plugged out of the computer USB port for about 5 seconds - Device’s factory default settings are: USB to RS232 and UART
Converter USB-RS232/RS485/UARTTTL - pdf
701.27 KB
SIRIUS PCB
11010100
3
pc
1+ 42.20 BGN
3+ 39.90 BGN
5+ 38.00 BGN
10+ 36.30 BGN
view more
Converter USB/RS485 Rev.1Image of Converter USB/RS485 Rev.1
Converter USB/RS485 Rev.1 - pdf
437.59 KB
SIRIUS PCB
11010069
5
pc
1+ 19.70 BGN
3+ 18.60 BGN
5+ 17.80 BGN
10+ 17.00 BGN
view more
Converter USB/RS485 Rev.2Image of Converter USB/RS485 Rev.2
Converter USB/RS485 Rev.2 - pdf
1.01 MB
SIRIUS PCB
11010070
15
pc
1+ 19.70 BGN
3+ 18.60 BGN
5+ 17.80 BGN
10+ 17.00 BGN
view more
Converter USB/RS485 Opto Rev.1Image of Converter USB/RS485 Opto Rev.1

Converter USB/RS485 Opto Rev.1


USB to RS485 Opto device is used for connection established between computer using USB port and devices with communication channel RS485. The system allows connecting several interface controllers to one commanding device. The device is based on CH340G and MAX485 chip. The RS485 interface used allows connecting up to 32 devices to one interface controller. Access controllers can be connected through FTP cable and the cable length must NOT exceed 1200 meters. Key Features: 2 or 3-Wire connection by RS485 Supply Voltage: 7÷24V DC Reverse-voltage protection USB and RS485 are galvanically isolated from one another Automatic data direction control Serial Speed: from 9600kbps up to 115200kbps LED indication for PWR supply voltage LED indication for RX, TX receiving and transmission PCB Size: 66mm х 21mm Supporting operating systems: Win XP, Win Vista, Win7, Win8, Win10, Linux,
Converter USB/RS485 Opto Rev.1 - pdf
534.43 KB
SIRIUS PCB
11010074
0
pc
1+ 26.90 BGN
3+ 25.50 BGN
5+ 24.30 BGN
10+ 23.30 BGN
view more
Converter USB/RS485 Opto Rev.2Image of Converter USB/RS485 Opto Rev.2

Converter USB/RS485 Opto Rev.2


USB to RS485 Opto device is used for connection established between computer using USB port and devices with communication channel RS485. The system allows connecting several interface controllers to one commanding device. The device is based on CH340G and MAX485 chip. The RS485 interface used allows connecting up to 32 devices to one interface controller. Access controllers can be connected through FTP cable and the cable length must NOT exceed 1200 meters. Key Features: 2 or 3-Wire connection by RS485 Supply Voltage: 7÷24V DC Reverse-voltage protection USB and RS485 are galvanically isolated from one another Automatic data direction control Serial Speed: from 9600kbps up to 115200kbps LED indication for PWR supply voltage LED indication for RX, TX receiving and transmission PCB Size: 66mm х 21mm Supporting operating systems: Win XP, Win Vista, Win7, Win8, Win10, Linux,
Converter USB/RS485 Opto Rev.2 - pdf
512.02 KB
SIRIUS PCB
11010075
0
pc
1+ 26.90 BGN
3+ 25.50 BGN
5+ 24.30 BGN
10+ 23.30 BGN
view more
Converter USB 2.0 Type A to RS485 ZK-U485Image of Converter USB 2.0 Type A to RS485 ZK-U485

Converter USB 2.0 Type A to RS485 ZK-U485


The Type-A to RS485 converter ZK-U485 with 5V output is an electronic module that converts USB signals to RS485 level serial signals to realize the communication between computers and microcontroller platforms, industrial equipment, PLC,
Converter USB 2.0 Type A to RS485 ZK-U485 - pdf
1.11 MB
SIRIUS PCB
11020036
1
pc
1+ 25.70 BGN
3+ 24.20 BGN
5+ 23.00 BGN
10+ 21.90 BGN
view more
Converter USB 2.0 Type A to RS485Image of Converter USB 2.0 Type A to RS485

Converter USB 2.0 Type A to RS485


The USB 2.0 Type A to RS485 converter is designed to convert virtual COM port and RS485 interfaces. Allows you to connect any external devices with RS485 output to a personal computer with a USB port. The USB 2.0 Type A to RS485 Converter enables the connection to a PC of devices managed using the RS-485
Converter USB 2.0 Type A to RS485 - pdf
1.46 MB
SIRIUS PCB
11020038
2
pc
1+ 19.70 BGN
3+ 18.60 BGN
5+ 17.80 BGN
10+ 17.00 BGN
view more
Touch Infrared Switch YK-SS004, 12VDC 60WImage of Touch Infrared Switch YK-SS004, 12VDC 60W

Touch Infrared Switch YK-SS004, 12VDC 60W


Description: Infrared contactless switch ON/OFF YK-SS004 for installation in profiles for LED strips. The sensor turns the light on when a hand passes near it and turns the light off when a hand passes it again. For the sensor to work, the profile diffuser must NOT be cut into its area. Connections to the power supply and the LED strip are made by soldering the wires in the places indicated on the device. Input voltage: 12VDC Maximum current: 5A Maximum switched power: 60W Maximum reach: 80mm Detection angle: 110° Dimensions:
Touch Infrared Switch YK-SS004, 12VDC 60W - pdf
213.12 KB
SIRIUS PCB
11020039
15
pc
1+ 13.20 BGN
3+ 12.45 BGN
5+ 11.85 BGN
10+ 11.34 BGN
view more
RF SMART Switch MS-101RImage of RF SMART Switch MS-101R

RF SMART Switch MS-101R


Operating Voltage: 90-250 V AC / 50-60 Hz;
Output Current: 10A;
Power: 2200W;
Bandwidth /Hz/: 433MHz;
RF SMART Switch MS-101R - pdf
4.03 MB
MS-101R
0
pc
1+ 14.30 BGN
3+ 13.00 BGN
5+ 11.95 BGN
10+ 11.44 BGN
view more
NEW
Wi-Fi SMART Switch MS-101Image of Wi-Fi SMART Switch MS-101

Wi-Fi SMART Switch MS-101


Operating Voltage: 90-250 V AC / 50-60 Hz;
Output Current: 10A;
Power: 2200W;
Bandwidth /Hz/: Wi-Fi 2.4GHz;
Wi-Fi SMART Switch MS-101 - pdf
4.03 MB
MS-101
38
pc
1+ 19.80 BGN
3+ 18.10 BGN
5+ 16.70 BGN
10+ 16.00 BGN
view more
NEW
Wi-Fi+RF SMART Switch MS-101Image of Wi-Fi+RF SMART Switch MS-101

Wi-Fi+RF SMART Switch MS-101


Operating Voltage: 90-250 V AC / 50-60 Hz;
Output Current: 10A;
Power: 2200W;
Bandwidth /Hz/: 433MHz, Wi-Fi 2.4GHz;
Wi-Fi+RF SMART Switch MS-101 - pdf
4.03 MB
MS-101WR
5
pc
1+ 28.90 BGN
3+ 26.50 BGN
5+ 24.55 BGN
10+ 23.62 BGN
view more
NEW
Wall Switch SYT-A1-W, RF 433 MHzImage of Wall Switch SYT-A1-W, RF 433 MHz

Wall Switch SYT-A1-W, RF 433 MHz


Operating Voltage: 3V Li battery CR2032;
Bandwidth /Hz/: 433MHz;
Wall Switch SYT-A1-W, RF 433 MHz - pdf
239.65 KB
SYT-A1-W
16
pc
1+ 11.20 BGN
3+ 10.20 BGN
5+ 9.39 BGN
10+ 8.97 BGN
view more
NEW
Wi-Fi+RF Smart Switch Module  MS-104 junction boxImage of Wi-Fi+RF Smart Switch Module  MS-104 junction box

Wi-Fi+RF Smart Switch Module MS-104 junction box


Operating Voltage: 90-250 V AC / 50-60 Hz;
Output Current: 10A;
Power: 2200W;
Bandwidth /Hz/: 433MHz, Wi-Fi 2.4GHz;
Wi-Fi+RF Smart Switch Module  MS-104 junction box - pdf
24.83 MB
MS-104
20
pc
1+ 32.30 BGN
3+ 29.70 BGN
5+ 27.53 BGN
10+ 26.47 BGN
view more
NEW
Wi-Fi Dimmer Switch Module  MS-105 junction boxImage of Wi-Fi Dimmer Switch Module  MS-105 junction box

Wi-Fi Dimmer Switch Module MS-105 junction box


Operating Voltage: 90-250 V AC / 50-60 Hz;
Output Current: 10A;
Power: 2200W;
Bandwidth /Hz/: Wi-Fi 2.4GHz;
Wi-Fi Dimmer Switch Module  MS-105 junction box - pdf
1.11 MB
MS-105
19
pc
1+ 39.60 BGN
3+ 36.30 BGN
5+ 33.62 BGN
10+ 32.36 BGN
view more
NEW
Wi-Fi Smart Plug SCHUKO 90-250VAC, 16AImage of Wi-Fi Smart Plug SCHUKO 90-250VAC, 16A

Wi-Fi Smart Plug SCHUKO 90-250VAC, 16A


Operating Voltage: 90-250 VAC / 50-60 Hz;
Output Current: 16A;
Power: 3500W;
Bandwidth /Hz/: Wi-Fi 2.4GHz;
Wi-Fi Smart Plug SCHUKO 90-250VAC, 16A - pdf
801.67 KB
WP-ZK-EU16M
9
pc
1+ 42.60 BGN
3+ 39.10 BGN
5+ 36.27 BGN
10+ 34.97 BGN
view more
Dynamic boiler controllerImage of Dynamic boiler controller

Dynamic boiler controller


Application: The Dynamic Boiler Controller is very suitable for water heating installations in family houses, small and large projects. It is designed to provide the desired heating comfort, optimizing the fuel consumption by a control of the boiler operation. In fact it is able to manage the operation of solid fuel, light fuel and gas boilers and as well the consumption of a heating energy from accumulating reservoirs or other central heating sources. Technical data: Controls the operation of solid fuel, light fuel or gas boilers. Can regulate the operation of the heating system in relation to the internal temperature of the heating system. Controls the heating system in compliance with: the outlet boiler temperature; the inlet boiler temperature of the return water; the water temperature in the heating circuit after the mixed four-way valve; the temperature in the domestic hot water circuit; the outdoor temperature; the room temperature by a room thermostats. Stops the boiler operation by a signal from the built-in working boiler thermostat, when the maximum working temperature exceeds (+75 °C)-(+90 °C). Opens the mixed four way valve, starts the circulation pump and stops the boiler if the outgoing boiler temperature exceeds its factory settings of (+95 °C)-(+105 °C). Closes the mixed four way valve and start the boiler operation by force (only in winter regime) if the return boiler water is lower than the fixed one of (+45 °C)-(+65 °C). Opens the mixed four way valve and starts by force the boiler operation if the water temperature after the mixed valve is lower than the adjusted one. The operation threshold will be changed automatically by the outdoor temperature and outdoor thermostat. If a room thermostat is not mounted this function can be used for a central equithermal temperature regulation of the water heating in multi-circuit systems and large projects. Opens the mixed valve, starts the circulation pump and stops the
Dynamic boiler controller - pdf
1.1 MB
INTIEL
INT0135
3
pc
1+ 695.00 BGN
Pellet burner and pellet boiler cotroller INT0173Image of Pellet burner and pellet boiler cotroller INT0173

Pellet burner and pellet boiler cotroller INT0173


Application: The controller is designed to provide automatic control of combustion process and power regulation of pellet burners, boilers and fireplaces. It is possible to attach to the controller additional modules of the series “Expansion modules for pellet boilers” according to the heating system: – Module for control of two heating circuits and DHW – Module for control of buffer and DHW. Convenient user interface via color touch screen. The controller can control the following units from the pellet burner system: – fuel supply auger 1 – fuel supply auger 2 – fresh air fan and flue gas fan – electric heater to ignite the pellets – cleaner to clean the ash – circulation pump – expansion modules for pellet boilers – lock menu against accidental access Protection: – protection against freezing of water – protection against overheating of the boiler and “back fire” – protection against blockage of the circulation pump Technical data: Power supply voltage: ~230V(+/- 10%)/50-60Hz Lighter outlet: ~230V/2KW Outlet circulating pump: ~230V/0.35KW Outlets for fans: 2 pieces х ~230V/0.25kW Output of augers: 2 pieces х ~230V/0.25kW Output cleaner / tubus: ~230V/0.25KW Sensor heating water: Pt1000 (form -50° up to +250°C) Flue gas sensor: Pt1000 (from -50° up to +250°C) Flame sensor: photoresistor Room thermostat input: independent contact Blocking thermostat input: independent contact Flow / rev. sensor input: independent contact / Hall sensor Display: color LCD with resolution 320 х 240 pixels Measuring range temperature: from -50 up to +350 °С Unit of measurement: 1°C Humidity of the environment: 0 – 80% Degree of protection: IP
Pellet burner and pellet boiler cotroller INT0173 - pdf
773.65 KB
INTIEL
INT0173
3
pc
1+ 418.00 BGN
Pellet burner and pellet boiler cotroller BISOLID INT0159
 
INTIEL
INT0159
3
pc
1+ 310.00 BGN
Heating circuits controller INT0129Image of Heating circuits controller INT0129

Heating circuits controller INT0129


Application: The device is designed to control motor actuators of mixed valves, in accordance with the water temperature directed to the heating system. It can be used also to keep the temperature in buffers or water tanks heated by a boiler by means of a mixed valve. Technical data: The heating water assignation is able to be adjusted in one of the following ways: independently (manually by the controller), by means of outdoor temperature or room thermo regulator Suitable room thermo regulator are contatct or analogue ones, as the analogue output can be 0(4) – 20 mA or 0 – 10V Suitable motor actuators are two way or proportional ones with a control signal of 0 – 10V The following limitations are to be fixed concerning the heating water: Minimum temperature; Maximum temperature; Minimum return water temperature Pump operation: if the heating water is within the fixed range for the minimum and maximum temperature operation by force in case the heating water temperature is less than 10 °С provide an overheating function of the circuit in case the heating water temperature exceeds its assigned level with 10 °С stops the circulation pump in case the temperature of the heating water is less than its minimum assigned level for period of 1 hour. After that the controller goes into test mode in which it starts the circulation pump for 5 minutes every 15 minutes. This mode continues until the heating water exceeds the assignation about its minimum temperature. Equipped with three temperature sensors
Heating circuits controller INT0129 - pdf
719.53 KB
INTIEL
INT0129
3
pc
1+ 348.00 BGN
Four channel controller for mixing valves INT0129-4Image of Four channel controller for mixing valves INT0129-4

Four channel controller for mixing valves INT0129-4


Application: The device is designed to control motor actuators for mixing valves, according to temperature, which is supplied to the rooms build by the mixing circuit. It is possible to control three two-position motor actuator and one analog motor actuator from 0 to 10 V. Suitable for buildings where there are one to four heating circuits , like: underfloor heating, radiator heating and prepare domestic hot water. Technical data: The heating water assignation is able to be adjusted in one of the following ways: independently (manually by the controller), by means of outdoor temperature or room thermo regulator. Room thermostats have to a contact output. Control four heatings circuit : three two-position motor actuators; one proportional motor actuator with analog output 0 – 10 V; The following limitations are to be fixed concerning the heating water: Minimum temperature; Maximum temperature; Minimum return water temperature Pump operation: if the heating water is within the fixed range for the minimum and maximum temperature operation by force in case the heating water temperature is less than 10 °С provide an overheating function of the circuit in case the heating water temperature exceeds its assigned level with 10 °С stops the circulation pump in case the temperature of the heating water is less than its minimum assigned level for period of 1 hour. After that the controller goes into test mode in which it starts the circulation pump for 5 minutes every 15 minutes. This mode continues until the heating water exceeds the assignation about its minimum temperature. Built-in weekly programmer. Equipped with six temperature sensors
Four channel controller for mixing valves INT0129-4 - pdf
605.17 KB
INTIEL
INT0129-4
3
pc
1+ 520.00 BGN
Controller for accumulation tanksImage of Controller for accumulation tanks

Controller for accumulation tanks


Application: The controller is designed to manage the heating of an accumulating tank in a central heating system, thus providing a smooth operation of the boiler, decreasing the number of its starts and stops. It manages directly the operation of a circulation pump between the boiler and the accumulation tank, as well it sends a signal for a boiler start and stop, and measures the temperatures at the top and lower part of the accumulation tank. Technical data: Manage operation of the circulation pump between the boiler and the accumulation tank Sends a signal for start and stop at the boiler Equipped with two temperature sensors Pt1000 (-50° up to +200°C) Monitoring of the following parameters: set and actual temperature at the top of the buffer. set and actual temperature at the bottom of the buffer. Temperature range of regulation from 0 °C up to 100 °C. Outputs – two relay / nominal current – 3A/~250V. output pump ~ 220V/50Hz output for start and stop the boiler Digital settings of main operation parameters. Possibility to lock the settings menu. Custom LED indication. “STOP”
Controller for accumulation tanks - pdf
754.79 KB
INTIEL
INT0129-2
3
pc
1+ 223.00 BGN



0700 18 880